NOTE: DO NOT attempt to switch between Imaging Software Platforms (i.e. If DEXIS or CDR Dicom for Windows is installed, it is automatically detected, and the Smart Image for. To remove an earlier version of Smart Image and install an update, click Download and Install. Click the Show Smart Image Preferences button, and then click Check for Updates. Open the Patient Chart, and then click the Smart Image tab.
Dexis Center Download From The
As always, all updates will still be available via WSUS, SCCM, and Windows Update this change is only for manual downloads. As of November 2016, Microsoft Windows Updates are now available for download from the Microsoft Update Catalog only. Zoom customers should feel confident they can continue to Zoom away and. Zoom has done a great job building the industry’s easiest to use product while ensuring best in class security. Download the latest version of the KaVo IO.1 DEXIS Titanium Sensor INSTALLATION GUIDEZoom has developed a strong set of advanced security features for its easy-to-use platform that any user should feel safe and comfortable deploying.
Simply insert this thumb drive into your computer to begin installation. Your DEXIS Titanium sensor comes with KaVo Software Manager on the USB Software Kit. If you are intalling a new Imaging Software for the 1st time, it is recommended to complete the instalation prior to installing your KaVo Software IO sensor drivers. Open your supported Imaging Software and verify that you have the minimum version installed. Contact your software manufacturer or KaVo Techical Support for software and installation instrutions.3 INSTALLATION STEPS - DEXIS and VixWin Users Log into your computer with an Administrator account.
Verify that your Imaging Software and KaVo IO Sensor Driver were successfully installed by viewing the KaVo Software Manager. Be sure to follow all prompts during the installation process. KaVo Software Manager will begin installing the latest version of both your Imaging Software and KaVo IO Sensor Driver. From the thumb drive, right click on the KaVo Software Manager shortcut and select Run As Administrator. If you no longer have access to your USB Software Kit, you will need to follow the steps in the section on the following page, to download the software and copy a version to your workstation. If your workstation is not connected to the inernet, you will need to contact DEXIS Technical Support.
Navigate to and download the latest version of your Imaging acquisition software, according to the version that you are currently using. Open your supported Imaging Software and verify that you have the minimum version installed. Reboot your computer to complete the software installation for your new DEXIS Titanium sensor.4 KAVO PORTAL INSTALLATION STEPS for CLINIVIEW Users and Users without USB Software Kit Access Log into your computer with an Administrator account.
After installation and reboot are complete, a sensor with a white background and a red X is displayed on the right side of the Windows Task Bar. NOTE: DTX Studio does not require the KaVo IO sensor driver to complete installation.5 SENSOR CALIBRATION FILES Your DEXIS Titanium calibration files are loaded on your device and automatically downloaded when connected. Call 833.DTX.CALL if you have any questions on the installation process.
Green indicates that all of the connected sensors are ready to operate. Red X indicates either: No DEXIS Titanium sensors are connected to computer Or one of the connected sensors is in an error state. This icon changes based on the status of your device.
You may open the Intra-Oral Sensor Dashboard to see the software load progress. Installation of the calibration files typically takes around three minutes to complete. STEP 2 The DEXIS Titanium sensor has the calibration files embedded on the device. NOTE: Right click this icon to open the Intra-Oral Sensor Dashboard. Connect your sensor to your computer s USB port to start the automatic download of the calibration files. Blue indicates that one of the connected sensors is acquiring an image.
Dexis Center Serial Number And
If a Windows user account does not have Administration rights, the software and drivers may not install properly for the Titanium sensor to work. The sensor is now ready for use in your Imaging Software.6 QUESTIONS Do I need Windows Administration rights and privileges to install the software and driver? Yes. This screen also displays driver and software versions. STEP 4 The Intra-Oral Sensor Dashboard also shows the serial number and state of the sensor.
Dexis Center License Manager O
Using the USB extension cable that came with your DEXIS Titanium kit could resolve these issues. The following folders need to be added for exceptions/exclusions: o C:\Program Files (x86)\dexis o C:\DEXIS o C:\Programdata\KaVo Kerr o C:\Program Files (x86)\kavo o C:\VixWin o C:\Program Files\DTX core o C:\Program Files (x86)\instrumentarium DENTAL\License Manager o C:\CVDATA (Image Path) o C:\Program Files (x86)\cliniview o C:\ProgramData\CliniView o C:\Program Data\PaloDEx Group o C:\ProgramData\FLEXnet o C:\Program Files (x86)\kavo Kerr Group o C:\Program Files (x86)\palodex Group o C:\Program Files (x86)\macrovision\flexnetactivationservice Why am I receiving an Error 101 or Fatal Error 10 message? Inconsistent USB power or data from a USB port can interrupt the PolarisAgent Service. Not doing so may cause the software and drivers to not operate correctly.